Video · 1:22

The Earth Spike, the Signal Clamp, and the Appliance Safety Check

The earth spike making the CAT more accurate, the signal clamp around a pipe or cable, and the safety check with the customer first.

Length

1:22

Added

2026-08-05

Transcript

Held, and searchable

Transcript

The whole recording in text, the same words Hertz answers from, so what you can watch you can also search and ask about.

0:00earth spike. The tone will change and the earth will weaken, making the CAT more accurate. Inside properties, the plug-in adapter can be used. Plug into an internal socket and connect the Genny. Please be aware that this device had its limitations. The plug-in adapter may not work on new builds because of the wiring systems. Also, properties with plug-in Wi-Fi systems have a negative effect on the signal that the CAT receives. If possible, ask the customer to disconnect the Wi-Fi system. An RCD should not be used in conjunction with the plug-in adapter. It has been known that the plug-in adapter has tripped the main fuse board. Please check with the

0:44customer for any safety critical electrical appliances. When using the signal clamp around a pipe or cable, ensure the jaws are completely closed. The cat needs to be at least 3 m away from the loop and Genny. When surveying, switch on the Genny and open and close the clamp. If the jaws are correctly closed, there will be a change in tone as the jaws make contact. Induction should be used after all previous methods have been exhausted. Place the Genny on the ground with the handle in line with the assumed route of the pipe or cable. The chevrons on the Genny need to line up with the chevrons